PFAS OnePrep Sample Preparation for Food Analysis
From Sample to Results in 3 hours

PFAS OnePrep | PFAS Sample Preparation for Food
PFAS Starter Kit Certified PFAS Cartridges▼ PFAS OnePrep for Food Analysis▼ PFAS Concentrators▼ Semi-Automated EZPFC ▼ EconoTrace- Water ▼ TurboTrace EPA 1633- Wastewater▼
PFAS OnePrep Sample Preparation for Food Analysis
From Sample to Results in Less Then 3 hours

PFAS OnePrep:
Automated PFAS Sample Preparation for Food
PFAS OnePrep sample preparation provides a fast, high-throughput, multi-channel solution for PFAS testing in food, fish, shellfish, meat, and other challenging solid and semi-solid matrices. As PFAS contamination in food continues to receive increased regulatory and analytical attention, laboratories need reliable PFAS sample preparation methods that provide high throughput, reproducibility, and accurate analytical results.
PFAS OnePrep sample preparation is designed to address the analytical challenges associated with per- and polyfluoroalkyl substances (PFAS), particularly in complex, high-fat, and protein-rich food matrices. Conventional PFAS sample preparation typically requires multiple independent steps for extraction, cleanup, purification, and concentration. These separate steps increase labor, sample handling, turnaround time, and the potential for contamination or analyte loss.
The PFAS OnePrep™ platform combines pressurized heated extraction, matrix cleanup, PFAS purification, and concentration into a single integrated workflow. The multi-channel system processes 4 samples simultaneously and is expandable to 8 samples, providing high-throughput PFAS sample preparation for food, fish, shellfish, meat, and other solid and semi-solid samples.
How PFAS OnePrep Works
Samples undergo controlled pressurized heated extraction, followed by integrated matrix cleanup and PFAS purification. Extracts are processed through PFAS-Prep cartridges for matrix-specific cleanup and PFAS purification, followed by automated concentration for downstream LC-MS/MS analysis.
Because extraction, cleanup, purification, and concentration are integrated into one continuous workflow, there is no vial-to-vial sample transfer during processing. This reduces manual handling, potential PFAS contamination, analyte loss, and operator-related errors.
PFAS OnePrep sample preparation delivers PFAS-ready extracts in under two hours and enables laboratories to progress from food sample to PFAS results in approximately three hours. Automatic documentation and real-time graphs of pressure and temperature provide complete process monitoring and traceability for each extraction run.
For laboratories performing PFAS testing in food, PFAS OnePrep provides a streamlined, high-throughput approach to PFAS extraction and sample preparation for food, fish, shellfish, meat, and other solid and semi-solid matrices—helping laboratories reduce hands-on processing, improve reproducibility, minimize contamination risk, and shorten PFAS testing turnaround time.
For more information on PFAS in food, see the U.S. Environmental Protection Agency (EPA) overview:
PFAS Explained – https://www.epa.gov/pfas/pfas-explained
Key Features
One-Step Integrated Workflow
Combines extraction, cleanup, purification, and concentration in one streamlined process.
Food-Matrix Optimized
Designed for complex food matrices, including meat, fish, shellfish, and processed foods.
Results in 3 Hours
From food sample to PFAS results in approximately 3 hours.
High-Throughput Processing
Processes 4 samples simultaneously and is expandable to 8 samples.
Reduced Contamination Risk
No vial-to-vial sample transfer minimizes contamination, sample loss, and handling.
Full Process Documentation
Records pressure, temperature, and other critical extraction parameters for every run.
Consistent & Reproducible
Provides reliable PFAS recovery and reproducibility across challenging food matrices.
LC-MS/MS Ready
Produces cleaned and concentrated extracts ready for direct LC-MS/MS analysis.
Easy to Operate
Simple workflow and minimal manual handling reduce training and operator errors.
Scalable Capacity
Modular design expands from 4 to 8 samples as laboratory throughput grows
3-Hour Workflow
Extract → Clean → Concentrate → LC-MS/MS Ready — All in <3 Hours
Sample In — Food / Meat / Fish
↓
Integrated Extraction
• Optimized for complex food matrices
• Real-time pressure & temperature monitoring
↓
Integrated Cleanup & Purification
• Removes matrix interferences
• No vial-to-vial sample transfer
↓
Inline Concentration
• Concentrates extract to PFAS-analysis levels
• Minimal operator handling
↓
Automatic Documentation
• Records pressure, temperature & extraction parameters
• Provides run documentation and traceability
↓
PFAS-Ready Extract
Ready for LC-MS/MS Analysis
PFAS OnePrep:
Automated PFAS Sample Preparation for Food
PFAS OnePrep sample preparation provides a fast, high-throughput, multi-channel solution for PFAS testing in food, fish, shellfish, meat, and other challenging solid and semi-solid matrices. As PFAS contamination in food continues to receive increased regulatory and analytical attention, laboratories need reliable PFAS sample preparation methods that provide high throughput, reproducibility, and accurate analytical results.
PFAS OnePrep sample preparation is designed to address the analytical challenges associated with per- and polyfluoroalkyl substances (PFAS), particularly in complex, high-fat, and protein-rich food matrices. Conventional PFAS sample preparation typically requires multiple independent steps for extraction, cleanup, purification, and concentration. These separate steps increase labor, sample handling, turnaround time, and the potential for contamination or analyte loss.
The PFAS OnePrep™ platform combines pressurized heated extraction, matrix cleanup, PFAS purification, and concentration into a single integrated workflow. The multi-channel system processes 4 samples simultaneously and is expandable to 8 samples, providing high-throughput PFAS sample preparation for food, fish, shellfish, meat, and other solid and semi-solid samples.
How PFAS OnePrep Works
Samples undergo controlled pressurized heated extraction, followed by integrated matrix cleanup and PFAS purification. Extracts are processed through PFAS-Prep cartridges for matrix-specific cleanup and PFAS purification, followed by automated concentration for downstream LC-MS/MS analysis.
Because extraction, cleanup, purification, and concentration are integrated into one continuous workflow, there is no vial-to-vial sample transfer during processing. This reduces manual handling, potential PFAS contamination, analyte loss, and operator-related errors.
PFAS OnePrep sample preparation delivers PFAS-ready extracts in under two hours and enables laboratories to progress from food sample to PFAS results in approximately three hours. Automatic documentation and real-time graphs of pressure and temperature provide complete process monitoring and traceability for each extraction run.
For laboratories performing PFAS testing in food, PFAS OnePrep provides a streamlined, high-throughput approach to PFAS extraction and sample preparation for food, fish, shellfish, meat, and other solid and semi-solid matrices—helping laboratories reduce hands-on processing, improve reproducibility, minimize contamination risk, and shorten PFAS testing turnaround time.
Key Advantages:
Key Features
One-Step Integrated Workflow
Performs extraction, cleanup and concentration in one unified process—eliminating multi-step manual handling and greatly reducing preparation time.
Food-Matrix Optimization
Engineered for high-fat and complex food matrices including meat, fish and processed foods. Effectively handles lipids, proteins and interfering compounds that impact PFAS recovery.
From Sample to Results in 3 Hours
Produces PFAS-ready test results in under 3 hours, reducing turnaround time from a full day to a single, simple, and quick batch cycle.
High-Throughput Capacity
Supports parallel processing of multiple samples to meet demanding laboratory workloads and high-volume PFAS food testing programs.
Low-Contamination System Architecture
Closed-container flow paths, PFAS-free components and minimal operator interaction reduce contamination risk, background levels and carry-over.
Validated Recovery & Reproducibility
Delivers consistent, trace-level PFAS recoveries with low RSD across diverse food matrices—meat, fish and composite food samples.
Regulatory-Ready Output
Generates PFAS extracts fully compatible with LC-MS/MS and adaptable to additional food-analysis platforms meeting national and international guidelines.
Easy Operation & Minimal Training
Simple workflow, clear steps and intuitive operation ensure rapid onboarding and fewer user-related errors.
Scalable for Any Laboratory Size
Works seamlessly with manual, semi-automated or fully automated sample-prep systems, allowing flexible expansion as testing volume grows.
3-Hour Workflow
Extract → Clean → Concentrate → LC-MS/MS Ready — All in <3 Hours
Sample In — Food / Meat / Fish
↓
Integrated Extraction
• Optimized for complex food matrices
• Real-time pressure & temperature monitoring
↓
Integrated Cleanup & Purification
• Removes matrix interferences
• No vial-to-vial sample transfer
↓
Inline Concentration
• Concentrates extract to PFAS-analysis levels
• Minimal operator handling
↓
Automatic Documentation
• Records pressure, temperature & extraction parameters
• Provides run documentation and traceability
↓
PFAS-Ready Extract
Ready for LC-MS/MS Analysis